FVE SolaX CommanderMonitoring • Diagnostics • Control • Modbus TCP

Compatibility

SolaX X3-Hybrid G4

The primary platform used to develop and test FVE SolaX Commander.

Compatibility with other SolaX inverter models and generations is neither guaranteed nor ruled out. Use on untested models is at the user's own risk. Functionality depends on the model, firmware, communication module and availability of the relevant registers.

Communication requirements

FVE SolaX Commander communicates via Modbus TCP, normally on TCP port 502. The computer must have network access to the inverter; under normal operation both devices are on the same local network (LAN).

Remote access and security

We strongly advise against exposing the inverter's communication port to the public internet without restrictions.

Just as FVE SolaX Commander can connect via Modbus TCP without knowing the administrator password, an unauthorized person may also connect if network access is configured incorrectly. Depending on the interface, they may read operating data, change settings and affect device operation.

For remote access, use a secure VPN connection. Any direct port exposure must be restricted by a firewall to specific trusted source IP addresses; this restriction alone does not encrypt communications. Entrust the configuration to a network specialist.

Support for additional devices

Extending support depends on the communication interface, available documentation and users' willingness to assist with practical tests of other device models and revisions.

Have you tested FVE SolaX Commander with an inverter other than the one listed here? Let us know how the program works and attach a screenshot of its window. We are especially interested in cases where the displayed values do not match the actual readings or the program behaves unexpectedly. Please include the exact inverter model and, if possible, its firmware version. Based on your feedback, we will try to adapt the program to other models.